FlowCytometricAnalysisofCellCycle
Fixation1) Collect 2 X 106 cells.2) Pellet cells by spinning at 1,000 rpm, 4°C for 5 minutes.3) Resuspend cell pellet in 1 ml of cold PBS.4) Fix cells by adding 4 ml of -20°C absolute ethanol.5) Store cells at -20°C in this fixation buffer until ready for analysis. (No more than 2 weeks)Staining6) Centrifuge (as above) fixed cells and resuspend pellet in 1 ml of PBS.7) Add 100 μl of 200 μg/ml DNase-free, RNaseA and i......閱讀全文
Flow-Cytometric-Analysis-of-Cell-Cycle
Fixation1) Collect 2 X 106 cells.2) Pellet cells by spinning at 1,000 rpm, 4°C for 5 minutes.3) Resuspend cell pellet in 1 ml of cold PBS.4) Fix cells
Flow-Cytometric-Analysis-Of-Bcl-Family-members
DescriptionCell Fixation, staining and flow cytometric analysis?ProcedureCells (106) were washed twice in FACS buffer (phosphate buffered saline PBS p
CELL-CYCLE-ANALYSIS
PROPIDIUM IODIDE: The most commonly used dye for DNA content/cell cycle analysis is PROPIDIUM IODIDE (PI). It can be used to stain whole cells or isol
Yeast-Cell-Cycle-by-Flow-Cytometry
ReagentsCold absolute ethanol.0.5 M Na citrate stock (filtered), 50mM diluted stock.10 mg/ml RNase A (Boil 10 mins, cool, filter and store at -20°C).4
FIXATION-and-DNA-Staining-for-Cell-Cycle-Analysis
BackgroundThis method of DNA staining utilizes ethanol to fix the cells and permeabilize the membrane, which allows the dye (Propidium Iodide) to ente
Cell-cycle-analysis-of-Escherichia-coli-cells
Cell cycle analysis of?Escherichia coli?cellsC period = the time for a round of chromosome replicationD period = the time between the end of a round o
Combined-Flow-Cytometric-Measurement-of-Two-CellSurface-Antigens
INTRODUCTIONFlow cytometry is frequently used to assess nucleic acid content?in individual cells. Based on DNA content alone, however, cells?in the qu
Flow-Cytometry-Analysis
PurposeFlow cytometry employs instrumentation that scans single cells flowing past excitation sources in a liquid medium. The technology can provide r
Combined-Flow-Cytometric-Measurement-of-Two-CellSurface-Antigens2
DNA and RNA Staining6. Stain cells with 7-AAD:?i. Resuspend the cells from Step?5 in 0.5 mL of NASS containing?10 μg/mL of 7-AAD. Incubatefor 20 min a
流式細胞儀技術專輯
Flow Cytometry Analysis?(Springer Lab, Harvard University)?Flow cytometry employs instrumentation that scans single cells flowing past excitation sour
流式細胞儀技術專輯
?最方便的實驗干貨查詢工具微信掃碼進入「丁香實驗」小程序編輯:?嗚咽分享到:??????Flow Cytometry Analysis?(Springer Lab, Harvard University)Flow cytometry employs instrumentation that scan
Staining-Procedure-for-Flow-Cytometric-Detection-of-Human-Cyclins
Staining Procedure for Flow Cytometric Detection of Human CyclinsThis is a standard protocol used at Pharmingen for Quality Control testing of the ant
Vybrant?-DyeCycle?-Ruby-stain
實驗概要Live cell studies ?of cellular DNA content and cell cycle distribution are useful to detect ?variations of growth patterns due to a variety of phy
Vybrant?-DyeCycle?-Violet-Stain
實驗概要Live cell studies ?of cellular DNA content and cell cycle distribution are useful to detect ?variations of growth patterns due to a variety of phy
An-Integrative-Procedure-for-Apoptosis-Identification-and-Measurement2
TroubleshootingCritical Steps(1) Don’t trypsinize cells for too long when collecting them.(2) Rotation speed should be no more than 1500 rpm during ce
Vybrant?-DyeCycle?-Green-and-Orange-Stains
實驗概要Live ?cell studies of cellular DNA content and cell cycle distribution are ?useful to detect variations of growth patterns due to a variety of ?ph
DNA-Cell-Cycle
Solutions70% ethanolribonuclease (100 μg/ml DNase free, Sigma)propidium iodide ( 50 μg/ml in PBS)ProcedureHarvest cells. Spin at 1200 rpm for 5 minute
細胞周期的流式細胞伩檢測實驗方法(PI,Brdu)1
ANALYSIS OF CELL CYCLE?Miriam Capri and Daniela Barbieri?Dept. Biomedical Sciences, Sect. General Pathology,Via Campi, 287, University of Modena, 4110
紅細胞裂解的實驗方法步驟
IntroductionPrior to using lymphoid tissue cell suspensions for flow cytometric analysis and/or for?in vitro?functional assays, it is recommended to r
Cyclins-and-Cell-Cycle-Regulation
The cell cycle is regulated by the interplay of many molecules. Key among these are the cyclins which are expressed and then degraded in a concerted f
流式應用精選——微核檢測(體內體外)
?注:點擊文章名稱查看詳情。文章名稱樣本儀器型號備注Assessment?of?the?Genotoxic?Potential?of?Azidothymidine?in?the?Comet,Micronucleus,?and?Pig-a?AssayBone?Marrow?and?Peripheral
Optimized-Method-for-the-Preparation-of-Rodent-Testicular-Cells2
Flow Cytometric AnalysisPrior to flow cytometric analysis, the vital dye Hoechst 33342 (Sigma-Aldrich, St. Louis, MO, USA) was added to cell suspensio
流式細胞儀高級技巧(Purdue)
?Introduction???A. CossarizzaWorkshop SponsorsMethods in analysis of apoptosis and cell necrosis.???Z. DarzynkiewiczCommon methods for measuring apopt
流式細胞儀高級技巧(Purdue)
Introduction???A. CossarizzaWorkshop SponsorsMethods in analysis of apoptosis and cell necrosis.??Z. Darzynkiewicz?Common methods for measuring apopto
Detection-of-Intracellular-Antigens-by-Flow-Cytometry
實驗概要Fix and Perm ?reagents are designed for use with all commercially available flow ?cytometers. Alignment and compensation should be performed accor
Intracellular-Cytokine-Staining-Protocol
實驗概要A ?modification of the basic immunofluorescence staining and flow ?cytometric analysis protocol can be used for the simultaneous analysis ?of surf
如何用流式細胞儀檢測線粒體數量
可以參考Mattiasson, G. (2004). "Flow cytometric analysis of isolated liver mitochondria to detect changes relevant to cell death." Cytometry A 60(2): 145-
An-Integrative-Procedure-for-Apoptosis-Identification-and-Measurement
IntroductionApoptosis is a normal physiological phenomenon put forward by Kerr [1]. It plays an important role in embryonic development, maintenance o
Analysis-of-murine-BM:-specimen-choice,-sampling-and-processing.
Histologic analysis of murine BM is a necessary complement to flow cytometric or in vitro analysis.?Techniques to do this are well established in huma
Analysis-of-murine-BM
Histologic analysis of murine BM is a necessary complement to flow cytometric or in vitro analysis.?Techniques to do this are well established in huma